The major misconception in Los Angeles is that homes burn down once flames arrive.

Reality:

60–90% of home ignitions occur from embers

CAL FIRE's Building in the Wildland guidance reports this estimated range. Embers can enter small openings or land on combustible materials ahead of the main fire.

Conditions to review for wildfire exposure include:

  • exposed wood-framed soffits

  • poorly detailed roof-to-wall joints

  • vented attics with unprotected openings

  • unsealed roof underlayments

  • combustible cladding over ventless assemblies

  • large glass walls with weak track systems

  • untreated steel that warps under radiant heat

  • foam insulation that melts or smolders

  • wall assemblies that trap heat and ignite internally

Wind-driven rain and hurricane design offer lessons about continuity and fastening, but wildfire exposure requires separate testing and detailing.

An impact or corrosion-resistance rating does not establish an assembly's wildfire performance. Select and detail products for each applicable exposure.

1. Wall & Envelope Assemblies:

Evaluate the Complete Wall Assembly

Wall framing, insulation, cladding, and drainage layers need to be evaluated together.

Review the full assembly for:

  • combustibility and listed fire performance

  • heat exposure and movement

  • moisture drainage and drying

  • continuity at penetrations

  • buildability and inspection

A coordinated envelope strategy can include the following, where appropriate for the design:

Envelope Details to Evaluate

  • Concrete or CMU cores in key structural areas for non-combustible mass.

  • Metal framing instead of wood in high-exposure elevations.

  • Continuous weather-resistive and air barriers with compatible transition details

  • Insulation selected for thermal, moisture, and fire performance within the assembly

  • Furring and drainage cavities detailed for drying and ember resistance

  • Cladding with the appropriate fire classification and installation details

  • Fasteners specified for corrosion resistance, structural loads, and material compatibility

Why this matters: fire performance depends on the complete assembly, detailing, exposure, and nearby fuels. A noncombustible component does not make a wall immune to fire damage.

The value is in coordinating the complete assembly before it is built.

2. Window & Slider Systems:

Select Glazing for the Required Exposure

Large expanses of glass can be vulnerable to radiant heat. CAL FIRE's home-hardening guidance addresses glazing, frames, and nearby combustibles as part of reducing that exposure.

For large sliders, review:

  • documented glazing and frame performance

  • track drainage and waterproofing integration

  • openings and weep details required by the tested assembly

  • movement and heat exposure

  • seal compatibility and service access

  • hardware corrosion resistance and maintenance

Wind, water, and wildfire exposure should be assessed separately.

Questions to Resolve Before Specifying Glazing

Frames → Verify the applicable fire and structural ratings.

Glass → Confirm the required glazing and assembly tests.

Perimeter joints → Coordinate air sealing and weatherproofing.

Hardware → Specify corrosion resistance, access, and maintenance.

Locking → Review closure and seal operation.

Tracks → Coordinate drainage, cleanability, and waterproofing.

An impact rating does not replace the applicable wildfire-related classification. Confirm the selected assembly with the design team and local building official.

The useful comparison is documented performance for the project's exposures.

3. Roofing Assemblies:

Roof Assemblies and Ember Defense

Review the roof for conditions such as:

  • tile over batten

  • vented eaves

  • ridge cap gaps

  • exposed underlayment edges

  • combustible fascias

  • unsealed gutters

These details need coordinated fire, wind, and water protection.

A project-specific roof assembly may include:

  • an appropriately designed sloped or tapered roof substrate

  • compatible adhered membranes with properly detailed laps and terminations

  • noncombustible soffits and protected eave details where required

  • engineered edge attachments

  • coordinated fascia details

  • metal gutter guards with a maintenance plan

  • copings and flashings compatible with the roof system

The design team should verify three separate performance questions:

How is ember entry resisted?

How will the assembly respond to the required fire exposure?

How are wind uplift and edge conditions addressed?

4. Mechanical Systems:

Mechanical Controls for Smoke Events

California's residential energy requirements address ventilation and filtration. Smoke-event operation also needs a documented strategy appropriate to the equipment; EPA's home guidance explains why intake controls and compatible filtration matter.

Coordinate normal ventilation and temporary smoke-event operation with the mechanical designer.

Air sealing, pressure balance, filtration, and equipment controls should be considered together.

Items to review include:

Mechanical Coordination

  • A pressure strategy suited to the enclosure and installed equipment

  • Documented ERV/HRV controls where those systems are installed

  • Outdoor-air intake controls appropriate to the equipment and operating strategy

  • MERV 13 or higher filtration where the system can accommodate it, consistent with applicable code and equipment requirements

  • Supply paths and filter-bypass control

  • Sealed service penetrations

  • Duct materials specified for the design and applicable requirements

Document the operating sequence and maintenance requirements before handover.

5. Hardscape, Landscaping & Site Strategy:

Site Design and Ongoing Maintenance

Review combustible materials near the structure as part of the applicable code and site plan, including:

  • wood planters close to walls

  • combustible fencing connected to the home

  • debris beneath decks and near vents

  • unprotected openings

  • combustible storage near the structure

Materials and details to assess include:

  • concrete terraces

  • stone veneers

  • metal fencing

  • non-combustible decking

  • vegetation located and maintained to meet defensible-space requirements

  • large-format pavers

  • protected slopes

These choices belong in a coordinated site plan, with maintenance and access addressed.

Specify the details during design.

Assign inspection and ongoing maintenance responsibilities before handover.

What This Means for Architects, Homeowners & Designers

1. Set Clear Project-Specific Resilience Objectives

Establish the applicable code requirements first, then document any additional project goals.

2. Coordinate Architectural Ambition With Tested Performance

Large glass → coordinate glazing, frame, and opening details.

Flat roofs → coordinate drainage, waterproofing, and fire requirements.

Cantilevers → coordinate structural, thermal, and envelope details.

3. Plan Material Compatibility and Maintenance

Corrosion-resistant and noncombustible materials can still be damaged. Ratings, detailing, exposure, and maintenance matter.

4. Reduce Avoidable Vulnerabilities Through Coordinated Detailing

Not thicker.

Not uglier.

Not fortress-like.

Just smarter.

A Final Word

Luxury homeowners in Los Angeles deserve homes that are both beautiful and defensibly built.

Bur Oak's approach is to coordinate architecture, materials, building science, and constructability for the project's actual exposure.

If you are planning a home in a wildfire-exposed area, start a project conversation about the site, design, and coordination requirements.

Sources